Złącze EPIC POWERLOCK F6 S L3/GY M40 (1) | 44420266 Lapp Kabel
| Kod | 1301651 |
|---|---|
| EAN | 4044774845876 |
| Kod Producenta | 44420266 |
| Producent | Lapp Kabel |
Złącze EPIC POWERLOCK F6 S L2/BK M40 (1) | 44420265 Lapp Kabel
| Kod | 1301650 |
|---|---|
| EAN | 4044774845883 |
| Kod Producenta | 44420265 |
| Producent | Lapp Kabel |
Złącze EPIC POWERLOCK F6 S L1/BN M40 (1) | 44420264 Lapp Kabel
| Kod | 1301649 |
|---|---|
| EAN | 4044774845890 |
| Kod Producenta | 44420264 |
| Producent | Lapp Kabel |
Złącze EPIC POWERLOCK F6 S N/BL M40 (1) | 44420263 Lapp Kabel
| Kod | 1301652 |
|---|---|
| EAN | 4044774845906 |
| Kod Producenta | 44420263 |
| Producent | Lapp Kabel |
Złącze EPIC POWERLOCK F6 S PE/GN M40 (1) | 44420262 Lapp Kabel
| Kod | 1301653 |
|---|---|
| EAN | 4044774845913 |
| Kod Producenta | 44420262 |
| Producent | Lapp Kabel |
Złącze EPIC POWERLOCK QP S M12 (1) | 44420242 Lapp Kabel
| Kod | 1301654 |
|---|---|
| EAN | 4044774846095 |
| Kod Producenta | 44420242 |
| Producent | Lapp Kabel |
Złącze okrągłe EPIC POWERLOCK QS 120 | 44420237 Lapp Kabel
| Kod | 1231742 |
|---|---|
| EAN | 4044774846132 |
| Kod Producenta | 44420237 |
| Producent | Lapp Kabel |
Styk skręcany /do obudowyEPIC POWERLOCK SS 120 (1) | 44420232 Lapp Kabel
| Kod | 1301655 |
|---|---|
| EAN | 4044774846170 |
| Kod Producenta | 44420232 |
| Producent | Lapp Kabel |
Złącze EPIC POWERLOCK D6 C L1/BN M40 | 44420218 Lapp Kabel
| Kod | 1230285 |
|---|---|
| EAN | 4044774846316 |
| Kod Producenta | 44420218 |
| Producent | Lapp Kabel |
Złącze EPIC POWERLOCK F6 C L1/BN M40 | 44420213 Lapp Kabel
| Kod | 1230282 |
|---|---|
| EAN | 4044774846361 |
| Kod Producenta | 44420213 |
| Producent | Lapp Kabel |
Obudowa wtyczki okrągła czarna IP68 EPIC M23 D6 7-13,5 | 44420037 Lapp Kabel
| Kod | 1135791 |
|---|---|
| EAN | 4044773767674 |
| Kod Producenta | 44420037 |
| Producent | Lapp Kabel |
Złącze wtykowe płytek drukowanych SLS 5.08/10/180FI SN OR BX | 1846290000 Weidmuller
| Kod | 1353505 |
|---|---|
| EAN | 4032248362578 |
| Kod Producenta | 1846290000 |
| Producent | Weidmuller |
Obudowy przepustów MC 1,5/ 8-G-3,5 | 1844278 Phoenix Contact
| Kod | 1300534 |
|---|---|
| EAN | 4017918113315 |
| Kod Producenta | 1844278 |
| Producent | Phoenix Contact |
Obudowa do złącz przemysłowych IE-CD-V14MRJ/VAPM24V-C-MA | 1068820000 Weidmuller
| Kod | 1341037 |
|---|---|
| EAN | 4032248823918 |
| Kod Producenta | 1068820000 |
| Producent | Weidmuller |
Termokurczliwy zestaw naprawczy ZMR-0-5żył | ZMR-0-5ŻYŁ Trytyt
| Kod | 1332481 |
|---|---|
| EAN | 5902768836189 |
| Kod Producenta | ZMR-0-5ŻYŁ |
| Producent | Trytyt |
Rura termokurczliwacienkościenna,+125 °C, RCH1 15,8/7,9x1-SZ szara (1m) | WRJCC1581790010030H1 Radpol
| Kod | 1162351 |
|---|---|
| EAN | 5907511935751 |
| Kod Producenta | WRJCC1581790010030H1 |
| Producent | Radpol |
Rura termokurczliwacienkościenna,+125 °C, RCH1 15,8/7,9x1-BR brązowa (1m) | WRJCC1581790010030B1 Radpol
| Kod | 1162349 |
|---|---|
| EAN | 5907511935317 |
| Kod Producenta | WRJCC1581790010030B1 |
| Producent | Radpol |
Końcówka kablowa miedziana, oczkowa, bez pokrycia galwanicznego LG 35/10 (50szt) | WOKMC0350001001 Radpol
| Kod | 1110099 |
|---|---|
| EAN | 5907511905846 |
| Kod Producenta | WOKMC0350001001 |
| Producent | Radpol |
Taśma elektroinstalacyjna TSE-1925NB niebieski | TSE-1925NB Trytyt
| Kod | 1290245 |
|---|---|
| EAN | 5901924530268 |
| Kod Producenta | TSE-1925NB |
| Producent | Trytyt |
Końcówka kablowa K45D 150/10 przekrój: 150mm2, otwór pod śrubę M10 /10 | E11KM-02030203502 Ergom
| Kod | 1158133 |
|---|---|
| EAN | 5900003766109 |
| Kod Producenta | E11KM-02030203502 |
| Producent | Ergom |
Końcówka oczkowa rurowa KM 10/12 przekrój: 10mm2, otwór pod śrubę M12 (opak 100szt) | E11KM-01010102700 Ergom
| Kod | 1263618 |
|---|---|
| EAN | 5900003107858 |
| Kod Producenta | E11KM-01010102700 |
| Producent | Ergom |
Koszulka termokurczliwa TGRK 52/20 | E05ME-01020200703 Ergom
| Kod | 1398460 |
|---|---|
| EAN | 5900003786817 |
| Kod Producenta | E05ME-01020200703 |
| Producent | Ergom |
Koszulka termokurczliwa TGR 18/6 czarna | E05ME-01020100303 Ergom
| Kod | 1160327 |
|---|---|
| EAN | 5900003786664 |
| Kod Producenta | E05ME-01020100303 |
| Producent | Ergom |
Puszka przeciwogniowa z membraną, hermetyczna, akustyczna śr.68 gł.50 z wprowadzeniem rur i przewodó | 86161007 Simet
| Kod | 1391098 |
|---|---|
| EAN | 4034338922396 |
| Kod Producenta | 86161007 |
| Producent | Simet |
Głowica konektorowa kątowa 630A, interface typu C, CTS 630A 36KV 35-95 mm2 | 355562 Cellpack
| Kod | 1150518 |
|---|---|
| EAN | 4010311172156 |
| Kod Producenta | 355562 |
| Producent | Cellpack |
Złącze solarne MC4 ZS 1500V 4-6mm2 kompletne (męskie i żeńskie) czarne (1szt) | 88.41 Elektro-Plast Opatówek
| Kod | 1406978 |
|---|---|
| EAN | 5905548287089 |
| Kod Producenta | 88.41 |
| Producent | Elektro-Plast Opatówek |
Puszka odgałęźna naścienna IP54 134x89x40mm E128, szara | E128 Spamel
| Kod | 1407825 |
|---|---|
| EAN | 4034338921900 |
| Kod Producenta | E128 |
| Producent | Spamel |
Puszka odgałęźna naścienna IP55 80x80x37mm E1200, szara | E1200 Spamel
| Kod | 1407824 |
|---|---|
| EAN | 4034338929241 |
| Kod Producenta | E1200 |
| Producent | Spamel |
Końcówka kablowa KMA 240/10 przekrój: 240mm2, otwór pod śrubę M10 | E13KC-01070104100 Ergom
| Kod | 1381755 |
|---|---|
| EAN | 5900003813940 |
| Kod Producenta | E13KC-01070104100 |
| Producent | Ergom |
Końcówki kablowe rurowe szczelne aluminiowo-miedziane typ:u KMA - KMA 150/8 | E13KC-01070102900 Ergom
| Kod | 1340757 |
|---|---|
| EAN | 5900003813858 |
| Kod Producenta | E13KC-01070102900 |
| Producent | Ergom |
Osprzęt łączeniowy to szeroka kategoria elementów do wykonywania, zabezpieczania i rozdzielania połączeń elektrycznych przewodów i kabli. Obejmuje końcówki kablowe, złączki, złącza wtykowe oraz puszki z akcesoriami montażowymi. Stosowany przez instalatorów, elektryków, tablicowców i służby utrzymania ruchu w instalacjach mieszkaniowych, komercyjnych i przemysłowych. Dobre połączenie ma niską rezystancję przejścia, jest odporne mechanicznie i bezpieczne w użytkowaniu, a od tego zależy trwałość całej instalacji.
Osprzęt łączeniowy dobiera się do przekroju i rodzaju żyły (drut czy linka), sposobu połączenia (zaciskane, śrubowe, sprężynowe lub wtykowe) oraz warunków pracy: wilgotności, temperatury, drgań i wymaganego stopnia ochrony IP. Inaczej wygląda dobór do instalacji w budynku mieszkalnym, a inaczej do szafy sterowniczej czy maszyny, gdzie połączenia muszą wytrzymać wibracje i częsty serwis. Przy doborze warto zwrócić uwagę na zgodność z normami produktowymi, m.in. PN-EN 60998 (urządzenia łączeniowe), PN-EN 60670 (puszki i obudowy osprzętu instalacyjnego) oraz PN-EN 61984 (złącza).
W ofercie osprzętu łączeniowego sklep.ke.pl znajdziesz: końcówki kablowe, puszki i akcesoria do puszek, złączki oraz złącza wtykowe.
Jak dobrać końcówkę kablową do przewodu?
Końcówkę dobiera się do przekroju żyły (mm²), jej rodzaju (drut lub linka) i miejsca podłączenia. Tulejki stosuje się do linek wprowadzanych w zaciski śrubowe i sprężynowe, a końcówki oczkowe lub widełkowe do mocowania pod śrubą albo na szynie. Średnica otworu końcówki musi pasować do śruby, a zaciskanie wykonuje się odpowiednimi praskami. Kolor izolacji często oznacza przekrój, ale schematy kolorystyczne różnią się między producentami i normami, więc zawsze sprawdzaj oznaczenie na opakowaniu.
Czym różni się złączka od złącza wtykowego?
Złączka służy do trwałego lub rzadko rozłączanego połączenia przewodów (np. złączka śrubowa, sprężynowa lub szybkozłączka). Złącze wtykowe pozwala szybko rozłączać i łączyć obwód bez narzędzi, dlatego stosuje się je tam, gdzie urządzenia są często demontowane, np. w oświetleniu, maszynach czy modułowych układach sterowania. Przy złączach wtykowych ważne są też prąd i napięcie znamionowe oraz liczba biegunów.
Jaką puszkę wybrać do instalacji?
Do montażu w ścianie stosuje się puszki podtynkowe (należy dobrać średnicę i głębokość). Na powierzchni, np. w garażach, piwnicach i pomieszczeniach technicznych, sprawdzają się puszki natynkowe. W miejscach wilgotnych lub narażonych na kurz i wodę, także na zewnątrz, potrzebne są puszki hermetyczne o odpowiednim stopniu ochrony IP. Wielkość puszki trzeba dopasować do liczby i przekroju przewodów, żeby mieć miejsce na prawidłowe ułożenie połączeń i swobodny dostęp do nich.